Product Characteristics:
Measure AC Current and Voltage, Measure the phase between two voltages, two currents, one voltage and one current. Indirectly measure the circuit power and power factor, Judge phase sequence. Clamp Dimension : φ7.5mm×13mm, AC Voltage Range: 0~20V/200V/500V, AC Current Range: 0~200mA/2A/20A, Phase Range: 0~360, resolution: 0.1mA /0.01V/1°.
Product Characteristics
Measure AC Current and Voltage, Measure the phase between two voltages, two currents, one voltage and one current. Indirectly measure the circuit power and power factor, Judge phase sequence. Clamp Dimension : φ7.5mm×13mm, AC Voltage Range: 0~20V/200V/500V, AC Current Range: 0~200mA/2A/20A, Phase Range: 0~360, resolution: 0.1mA /0.01V/1°.
. Technical Specifications
1. Baseline Conditions and Working Conditions
Influence Factor | Baseline Condition | Working Condition | Remarks |
Ambient Temperature | 23°C±1°C | -10°C~40°C | |
Ambient Humidity | 40%~60% | <85% | |
Waveform | Sine | Sine | β=0.05 |
Signal Frequency | 50HZ±1Hz | 45HZ~65Hz | |
Meter Power Supply | 9V±0.1V | 9V±1V | |
External Electric and Magnetic field | Should avoid | ||
Tested Wire Location | The tested wire should be located in the clamp approximate geometric center |
2. General Specification
Function | Phase, AC current, AC voltage, AC leakage current, Direct phase sequence test; Transformer group, Inductive and Capacitive Circuit judgment; Power factor, Power indirect test |
Power Supply | DC9V Alkaline batteries (1.5V AA×6) |
Power Consumption | Maximum 35mA when backlight is on, Battery continuously working for 40 hours |
5mA when backlight is off, Battery continuously works for 300 hours | |
Display Mode | LCD display, Blue backlight |
LCD Size | 70mm×62mm |
LCD Display Domain | 64mm×54mm |
Meter Size | L×W×T: 196mm×92mm×54mm |
Clamp Dimension | φ7.5mm×13mm |
Sample Rate | 3 Times/Second |
Range | AC voltage: 0~20V/200V/500V |
AC current: 0~200mA/2A/10A | |
Phase: 0~360 | |
The Tested Signal Amplitude Scope in Phase Measurement | Phase U1-U2: 30V~500V |
Phase I1-I2: 10mA~10.00A | |
Phase U1-I2 or I1-U2: 10V~500V, 10mA~10.00A | |
Reading Hold | Press key HOLDto hold the reading, and “DH”displays on the screen |
Auto Power off | 15 minutes after boot |
BatteryVoltage Detection | When battery voltage is lower than 7.8V, Low batter symbol will display on the screen to remain battery replacement |
Weight of Meter | Host: 550g (with batteries), Clamp: 170g×2 PCS, Voltage Test line 250g |
Length of Test Line | 1.5m |
Length of Current Clamp Lead | 2m |
Working Temperature and Humidity | -10°C~40°C; below 80%Rh |
Storage Temperature and Humidity | -10°C~60°C; below70%Rh |
Input Impedance | U1 or U2 Voltage testing: 2MΩ |
U1U2 phase testing is: 40 KΩ | |
Voltage-Resistance | One minute tolerant duration between meter PCB and shell with 1000V/50Hzsine wave AC voltage input. One minute tolerant duration when input 500V/50Hz sine wave AC voltage between the U1 and U2 input electrodes |
Insulation | Between meter inner PCB and shell: ≥10MΩ, Between both voltage Inputs: ≥10MΩ |
Structure | Dual Insulation |
3. Basic error and performance indicators under baseline conditions
Items | Range | Resolution | Tolerance |
Voltage | 20V | 0.01V | ±(1.2%rdg+2dgt) |
200V | 0.1V | ||
500V | 1V | ||
Current | 200mA | 0.1mA | ±(1.0%rdg+2dgt) |
2A | 1mA | ||
10A | 10mA | ||
Phase | 0~360° | 1° | ±3° |
. Configuration List
Meter | 1 Piece |
Meter box | 1 Piece |
Current clamp | 2 Pieces |
Test line | 4 Pieces (2 pieces in Red and 2 pieces in Black) |
Battery | 1.5V AA, 6 Pieces (alkaline battery: 1.5V AA) |
. Field Application